Brand Name : ESTEL

Model Number : EMGA1500D1

Certification : ISO,ROHS, CE

Place of Origin : China

MOQ : 1 Set

Price : Depending on order quantity

Payment Terms : L/C, T/T, Paypal

Supply Ability : 2000 Sets per month

Delivery Time : 20 days

Packaging Details : Wooden Case + Pallet

External Dimension(W×H×D) : 680*570*250mm

Cooling Capacity (L35/L35) : 1500W

Heating Capacity(Optional) : 1000W

LCD Display : Used for Dual LCD display

Application : Cooling for outdoor kiosk

IP Grade : IP55

Refrigerant : R134a

Weight : 29KG

Contact Now

1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU

1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU Introduction

The air conditioner is one kind of refrigeration product self-developed for cabinet. It is applicable in
the place where the cabinet internal heat is very large, the internal electronic equipment is sensitive to the
environment temperature and which should be isolated internally and externally completely. This product
has multiple functions, high reliability, and has the feature that it can start to work without complex
debugging after powering.
The fan in the internal cycle air path absorbs the hot air from the upside to make air heat exchange
by evaporator fins, and sends the cooled air from the downside of the air conditioner. By so, the air in
cabinet can cycle to achieve the purpose of lowering the temperature. Meanwhile, The fan in the external
cycle air path absorbs the external cold air from the downside, and discharges the hot air from the upside
after heat exchange.
1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU
1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU Technology Parameters
Item Name Unit Parameter
Dimension and installation Body outline dimension
(width*height*depth )
mm 680*570*250
Outline dimension including
flange(width*height*depth )
mm /
Weight Kg 29
Installation method Door Mounted
Installation method Outdoor
Environment and protection Working environment temperature -40 to +55
Noise dB(A) 62
Life expectancy Years >10
IP grade IP55
Refrigerant R134a
ROHS certification yes
Performance Input voltage range 220 VAC±15% ~/50Hz
Refrigerating capacity(L35/L35) W 1500
Rated Refrigerating input
power(L35/L35)
W 580
Rated Refrigerating current (L35/L35) A 2.6
Maximum Refrigerating current A 5.3
Heat capacity(optional) W 1000W
Air Volume of Inner Circulation m3/h 640
1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU Standards
NO. Standard No. Standard Name
01 GB 4208 Enclosure Protection Class
02 GB/T 4857.5,9,10,11,16 Packaging-Basic tests for transport packages
03 GB/T 2423.1,2,3,8,10,17,38 Electrical and electronic products environmental test
04 GB9254-1998 Information technology equipment-Radio disturbance
characteristics-Limits and methods of measurement
05 GJB150-86 Environmental test methods for military equipments
06 GB/T17626.8 Electromagnetic compatibility-Testing and measurement
techniques--Power frequency magnetic field immunity test
07 YD/T 2768-2014 The temperature controlling devices for Communication outdoor room 1st parts: Embedded temperature controlling
devices
08 EN 55022:2006+A1:2007 Conducted Emission and radiation test
09 EN 61000-3-2:2006+A2:2009 Harmonic Current
10 EN 61000-3-3:2008 Voltage Fluctuation and Flicker
11 EN 61000-4-2:2009 ESD
12 EN 61000-4-3:2006 Radiation disturbance Immunity Test
13 EN 61000-4-4:2004 Electrical Fast Transient Burst
14 EN 61000-4-5:2006 Surge
15 EN 61000-4-6:2009 Conduction disturbance Immunity Test
16 EN 61000-4-11:2004 Voltage dips and short interruptions

Installation diagram
1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU
Note: the installation diagram is just for reference, the specific installation scheme should be
determined according to the environment of the actual usage.
Product function:
1. Cooling
When the temperature inside cabinet is higher than refrigeration starting temperature, it starts
refrigerating; when the temperature inside cabinet is lower than refrigeration stopping temperature, it
stops refrigerating.
User parameter setting point
Parameter Default value Setting range Unit Note
Refrigeration starting temperature 35 [20~40] Refrigeration stopping temperature =Refrigeration starting temperature- Refrigeration return difference
Refrigeration return
difference
6 [3~10]

2. Heating(Optional)


When the temperature inside cabinet is lower than heating starting temperature, it starts heating; when the temperature inside cabinet is higher than heating stopping temperature, it stops heating.
User parameter setting point

Parameter Default value Setting range Unit Note
Heating starting temperature 5 [-10~15] Heating stopping temperature= Heating starting temperature+
Heating return difference
Heating return difference 10 [3~15]

3. Remote monitor


Air conditioner has an RS485 communication interface, supporting MODBUS- RTU communication protocol.The air conditioner communicates with the upper monitor through the RS485 communication interface. Or users can check the air conditioner’s running state by viewing the display screen directly and change its running parameters.
4.4 The control of external fan (Optional)
According to the optional requirement, the external fan (Hydrogen discharge / emergency fan) automatically realizes cycle hydrogen discharging and emergency ventilation function.
Hydrogen discharge function(Optional):When hydrogen discharge cycle comes, air conditioner start

the hydrogen discharge fan, the control switch closes.
hydrogen discharging

parameter Default value Setting range Unit
cycle 24 [0~72] h
discharging time 5 [0~10] Min

Emergency ventilation function (Optional):

When the temperature inside cabinet is higher than Emergency ventilation starting temperature, emergency ventilation fans run; when the temperature inside cabinet is lower than Emergency ventilation stopping temperature, emergency ventilation fans stop.
Emergency ventilation function

parameter Default value Setting range Unit
starting temperature 45 [28~50]
stopping temperature 42 [25~50]

Product Tags:

MODBUS- RTU Kiosk Air Conditioner

      

Kiosk Air Conditioner With Remote Monitor

      

1500W Kiosk Air Conditioner

      
Quality 1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU for sale

1500W Kiosk Air Conditioner For Outdoor Kiosk With Remote Monitor Support MODBUS- RTU Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)